₹3,675 – ₹3,938
Prices are inclusive of Delivery Charges.
PID-903 – Temperature and Process Controller
Configuration : (1AI + 2DO + 1AO)
Size (mm) : 96 x 96 x 75
Libratherm offers various models of Digital Temperature and Process PID Controllers. The user has the choice of selecting the model based on the type of Input, type of analog or digital interface, and required size. All the models are designed to suit most of the Industrial applications.
This High-Temperature PID Controller is available in the size of 96 x 96 x 75 mm, accepts input from J, K, thermocouple, Pt-100, 4-20mA, and provides SSR output, 4-20mA output, 1 relay output.
AI | Analog Input from Process transmitter in the form of 4-20mA or from the Temperature Sensors. |
AO | Analog Output proportional to Analog input, available in the form of Retransmission or PIDÂ control output of 4-20mA or optionally 0 -10V |
DO | Digital Output in the form of relay contacts or SSR DC logic level |
SO | Serial Output in the form of RS-485 on MODBUS RTU interface. |
Paramters | Description |
---|---|
Process Input (AI) | 4-20mA or 0-10V |
Display Range | -2000 to +2000 or 0 to 4000 count with programmable decimal point |
-1999 to +9999 with programmable decimal point (5 Digit models) | |
Resolution | 0.1,0.01,0.001 |
Temperature Input(AI) | Thermocouple type – J, K, R, S, B |
RTD type – (Pt-100)/ 2, 3 or 4 wire sensors | |
Temperature Range | As shown in the Input and Range Selection table. |
Resolution | 1 °C for thermocouples and 0.1 °C for Pt-100. |
Sampling rate / Display rate | The input is read @40mS / the display is updated @1 second. |
Indicating Accuracy | +/- 1 °C for Thermocouple throughout the range and +/- 0.1 °C for Pt-100 for (4-20)mA or (0-10)V - absolute to the linear input signal. |
Display | 4 digit 0.5" Red 7-segment display for process variable. |
4 digit 0.5" Green 7-segment display for set value and PID parameters | |
Settings | Using Front panel feather touch key board to set various parameters like Set values, Hysterisis values, Span hi/lo values, MODBUS slave ID, Input selection, calibration etc |
PID Values | Prop. Band (P) = 0.0 to 100.0% of Span, Integral (I) = 0.00 to 5.00 resets/minute, Derivative (D) = 0.00 to 5.00 miutes, CYC= 2 to 30 secs |
Control Action | Analog and Switching PID algorithm |
(Direct or Reverse action as required) | |
Control Output | 1. SSR drivers 2. 4-20mA/0-5V/0-10V |
Alarm Output | 1 to 4 no. of Relays for event or High/Low Alarms |
Retransmission Output (AO) | 4-20mA linearized and proportional to the selected input type and range. RL max = 300 Ohms. |
2nd Analog Output Not available if used for Control Output. | |
Serial Output (SO) | RS485 on MODBUS protocol with programmable slave ID |
Supply | (90VAC-250VAC), 50/60 Hz, 18 to 48VAC/DC (optional) |
Size | 96 x 96 x 75 |
Enclosure | ABS plastic with polycarbonate front graphic. |
Sr. No. | Specifications | Part No. |
---|---|---|
1.1 | Input : J,K,Pt-100,4-20mA + SSR + 4-20mA control output + 2 Relay output | 1505-1 |
1.2 | Input : J,K,Pt-100,4-20mA + SSR control output + 2 Relay output with 4-20mA retransmission | 1505-2 |